QuickNet-RK Installation Instructions
5
Strip 1/2" of insulation off both ends of each jumper wire.
Slide SolderSleeve connector onto one heating wire.
Insert jumper wire into SolderSleeve connector.
Heat SolderSleeve connectors until solder and adhesive have
melted. (The colored solder ring will turn clear when melted.)
Allow to cool, then repeat for second jumper wire.
Slide two heat-shrinkable tubes onto each jumper wire.
Slide SolderSleeve connector onto one heating wire.
Insert jumper wire into SolderSleeve connector.
20
21
22
23
24
Cut jumper wires to length allowing for 1/2" overlap on each
end as shown.
19
1/2"
1/2"
1/2"
Heating
wire
SolderSleeve
Jumper
wire